Skip to Content | Accessibility Assistance
Printing Header
Project Name: Canon Manor West Assessment District Improvements

Project # W06001

 April 3, 2006

SONOMA COUNTY
DEPARTMENT OF TRANSPORTATION AND PUBLIC WORKS
SANTA ROSA, CALIFORNIA

NOTICE TO PLANHOLDERS
FOR CONSTRUCTION OF

CANON MANOR WEST ASSESSMENT DISTRICT IMPROVEMENTS 

COUNTY PROJECT NOS. W06001, W06002, W06003

ADDENDUM NO. 5

I.    Changes to Plans and Special Provisions 

      Changes to Plans and Special Provisions as per attached sheets.

Please fill out the Addendum Acknowledgment sheet (page BB-9 of the Bidder's Book, Volume 1 of 3) verifying your receipt of this Addendum (Addendum No. 5). 

DAVID D. KNIGHT, DIRECTOR
DEPARTMENT OF TRANSPORTATION AND PUBLIC WORKS
 

__John Maitland________________
John Maitland, P.E.
Division Manager


Attached Pages:

SCHEDULE A -    PUMP STATION 

Sheet 7 of 24
Delete Type C, D, & E trench section and trench dimension chart.
Delete Backfill and bedding shown on Type A trench section.
All backfill and bedding shall be per City of Rohnert Park Standards  

SCHEDULE A -    TRUNK SEWER & FORCE MAIN  

Sheet 17 of 20
The existing storm drain crossing the trunk sewer at Sta 170+90 and Sta 174+75 is a 54” pipe.
The existing storm drain crossing the trunk sewer at Sta 172+50 is a 18” pipe.

Sheet 1 of 20
Delete Note 22
“If a street has been cut to install utilities or to match existing pavement, the street shall be slurry sealed in accord with standard specifications of the State of California Section 37-2.  The extent of area to be sealed shall be determined by the Superintendent of Public Works or the City Inspector.”

Sheet 4 of 20
SSMH No. 1A shall be HDPE lined.  Cost shall be included in Bid Item. 
No. 16A 60” sewer manholes. 

SCHEDULE B -   SANITARY SEWER AND DRAINAGE IMPROVEMENTS 

Sewers and storm drains inside roadways shall be in accordance with Rohnert Park Specifications.
Storm drains outside of roadway shall be bedded in accordance with Rohnert Park Specifications; except NATIVE MATERIAL IS ALLOWABLE above the bedding Compacted to 90% RC. 

Sheet 2 of 40
General Notes
Add:    All storm drain culverts noted on Sheet 4 and storm drain noted as CL4 in profiles on Sheets 29 & 38 of 40 shall be RCP CL4.
All other storm drain shall be plastic.

Sheet 1 of 40 
Clearing limits shall be as noted on typical section and shall include clearing required for new driveways noted on Driveway Table shown on sheet 4.
Existing trees 6” and greater to be removed are noted on plans.  All trees, landscaping and improvements outside of the clearing limits are to remain.
Landscaping, fences, irrigation systems and other improvements inside of the clearing limits are not required to be replaced. 

SCHEDULE C -   WATER MAIN PROJECT 

Sheets 24, 25, 26, 27, 28 of 29 
Sturtevant Drive
The lineal frontage of water MAINS shown represents total length of pipe even though there may be slight gaps in the match lines along the street.

Sheet 1 of 29 
General Note 1
Add: Except as noted herein including backfill as shown on sheet 29 of 29.

Sheet 29 of 29 
Sampling tap shall be a curb stop installed inside a standard single meter box.

BOOK 1 OF 3  

Special Conditions – Page SP 83
Utility boxes shall be for standard residential utility splices.

Item 41B Utility Trench/conduit shall be standard residential utility trench including conduits for secondary electrical, telephone and gas only. 

Item 43B Utility Trench Cap shall be 3’ wide x 3” thick CDF including split conduit for telephone cables and a 3’ minimum length per crossing.

BOOK 2 OF 3 

Section 2315
Delete Part 2 Products
All backfill in Schedule A shall be per Rohnert Park Specifications

Delete Section 3.3 Pipeline and Utility Trench Excavation. 

ADDENDA NO. 3 

Detail A referred to on page 4 of 19 Addenda No. 3 is attached.


Revised Details



Construction Clarification Letter from Consultant