County of SonomaCounty of Sonoma Department of Health Services  
Sonoma Coast

Flooring for Food Establishments

 

CURFFL | Full Kitchens | Limited Prep Areas | Dry Storage | Walk-Ins | Floor Drains

 

When installing a new floor or replacing an existing floor, contact Sonoma County Environmental Health to assure the floor and base meet the current requirements.

The California Uniform Retail Food Facility Law (CURFFL) Section 114150 (a) states the following:

Except in sales areas of retail food establishments and as otherwise provided in subdivision (d), the floor surfaces in all areas in which food is prepared, packaged, or stored, where any utensil is washed, where refuse or garbage is stored, where janitorial facilities are located, and, except with respect to areas relating to guestroom accommodations and the private accommodations of owners and operators in restricted food service transient occupancy establishments, as defined in Section 113870, in all toilet and handwashing areas, and in employee change and storage areas shall be smooth and of durable construction and nonabsorbent material that is easily cleaned. These floor surfaces shall be coved at the juncture of the floor and wall with a 10 millimeter (3/8 inch) minimum radius coving and shall extend up the wall at least 10 centimeters (4 inches) except in areas where food is stored only in unopened bottles, cans, cartons, sacks, or other original shipping containers.

Top of page

The following floor types will meet the above CURFFL requirements:

Full kitchens (containing cooking equipment), sculleries, meat or fish preparation areas, bars, bakeries, and any areas with a power wash down:

  1. Quarry tile with a 4" quarry tile coved base. Epoxy grout is recommended.
  2. Troweled on epoxy floor (not paint) with a 4" self-coved base.
  3. 100% homogenous vinyl flooring recommended by the manufacturer for use in commercial kitchens, such as Altro? 25. The floor must have heat-welded seams and a 4" self-coved base.

Top of page

Limited food preparation areas, service areas and restrooms such as delicatessens, sandwich shops, espresso shops, areas behind service counters, employee change areas and janitorial rooms:

  1. Those floors listed above for full kitchens.
  2. The minimum flooring required is a commercial grade sheet vinyl, such as Congoleum Marathon or Armstrong Corlon, containing a composition backing (felt backing) having chemically-welded seams with a 4" self-coved base.

Top of page

Dry storage areas (all prepackaged, no open food containers, no food preparation, no sinks, no refrigerators and no ice machines):

  1. Those floors listed for full service kitchens and limited food preparation areas.
  2. The minimum flooring required is vinyl composition tile with a 4" vinyl top set coved base.

Top of page

Walk-in refrigerators and freezers:

  1. Metal floor and coved base installed as part of the NSF or equivalent walk-in.
  2. Quarry tile with a coved base supplied by the walk-in manufacture. Epoxy grout is recommended. The coved base supplied by the walk in manufacture should be used on the outside of the walk-in if the walk in is located within the kitchen.
  3. Seamless trowled on epoxy (not paint) with a coved base supplied by the walk-in manufacturer.
  4. Smooth, sealed concrete with 4" coved concrete base or a coved base supplied by the walk-in manufacturer.

Top of page

Floor Drains

Upon new construction or extensive remodeling, floor drains shall be installed as follows:

  1. In floors that are water-flushed for cleaning.
  2. In areas where pressure spray methods for cleaning equipment are used.

In rest rooms, floor drains are recommended, but not required.

If you have further questions, contact Jim Tyler, Environmental Health Specialist III, at (707) 565-6544, FAX (707) 565-6525, or e-mail jtyler@sonoma-county.org.

Top of page

 

Questions, comments, suggestions? Send us email.

 



This page was last updated  by Webmaster